Procedural characteristics of pulmonary vein isolation with high

Procedural characteristics of pulmonary vein isolation with high

4.9
(335)
Write Review
More
$ 23.00
Add to Cart
In stock
Description

The purpose of this study was to investigate the safety and efficacy of high-power short-duration (HP-SD) ablation compared to conventional ablation in patients with atrial fibrillation (AF). We enrolled consecutive 158 drug-refractory symptomatic AF patients (119 males, mean age 63 ± 10 years) who had undergone first radiofrequency pulmonary vein isolation (PVI). PVI was performed using the conventional setting (20–35 W) in 73 patients (Conventional group) and using the HP-SD setting (45–50 W) in 85 patients (HP-SD group). The rate of first pass isolation, remaining gaps after circumferential ablation, dormant conduction, and the radiofrequency application time in each pulmonary vein (PV) were compared between the groups. The first pass isolation ratio was significantly higher in the HP-SD group than in the Conventional group (81% vs. 65%, P = 0.027) in the right PV, but did not differ in the left PV. The remaining gaps were fewer in the right superior PV (4% vs. 21%, P = 0.001) and left inferior PV (1% vs. 8%, P = 0.032) areas, and the radiofrequency application time in each PV was shorter (right PV, 12.0 ± 8.9 min vs. 34.0 ± 31.7 min, P < 0.001; left PV, 10.6 ± 3.6 min vs. 25.7 ± 22.3 min, P < 0.001) in the HP-SD group than in the Conventional group. The use of the HP-SD setting might contribute to improve the first pass isolation rate and to shorten the radiofrequency application time in each PV.

Pulsed-Field Ablation: A New, Highly Selective Catheter Ablation

Cardiac Arrhythmia Mapping System Clinical Data – RHYTHMIA HDx

Comparison of very high‐power short‐duration, high‐power short‐duration, and low‐power long‐duration radiofrequency ablation for atrial fibrillation: A systematic review and network meta‐analysis - Junarta - Pacing and Clinical Electrophysiology

The relationship between the heparin dosing during catheter ablation

Catheter Ablation for Atrial Fibrillation Overview

PDF) Globe Pulsed Field System for High-definition Mapping and

Radiofrequency ablation - Wikipedia

PDF) Optimal interruption time of dabigatran oral administration to ablation (O-A time) in patients with atrial fibrillation: Integrated analysis of 2 randomized controlled clinical trials

Autonomic cardiogastric neural interaction after pulmonary vein isolation in patients with atrial fibrillation

Procedural characteristics of pulmonary vein isolation with high

Focus on EP Single-shot Techniques For Pulmonary Vein Isolation