Sternal closure with sandwiched three-piece bioresorbable mesh

Sternal closure with sandwiched three-piece bioresorbable mesh

4.9
(253)
Write Review
More
$ 23.99
Add to Cart
In stock
Description

Background Median sternotomy is the most performed procedure in cardiac surgery; however, sternal displacement and bleeding remains a problem. This study aimed to investigate whether sternal reconstruction using a sandwiched three-piece bioresorbable mesh plate can prevent postoperative sternal displacement and bleeding more than a bioresorbable pin. Methods Patients (n = 218) who underwent median sternotomy were classified according to whether a sandwiched three-piece bioresorbable mesh plate and wire cerclage (group M, n = 109) or a bioresorbable pin and wire cerclage (group P, n = 109) were used during sternal reconstruction. The causes of postoperative sternal displacement and bleeding with computed tomography data were analyzed and compared between the groups. Results The preoperative patient characteristics did not significantly differ between the groups. However, the evaluation of sternal and substernal hematoma on postoperative day 5 using computed tomography showed sternal displacement in 4 (4%) and 22 (20%) patients, and substernal hematoma in 17 (16%) and 41 (38%) patients in groups M and P, respectively; this difference was significant. Furthermore, the amount of bleeding at 6 h postoperatively was lower in group M than in group P (235 ± 147 vs. 284 ± 175 mL, p = 0.0275). Chest reopening, intubation time, and length of intensive care unit and hospital stays did not differ between the groups. The evaluation of substernal hematoma based on computed tomography yielded a significantly lower for group M than for group P, revealing that the mesh plate was an independent predictor of substernal hematoma prevention. Conclusion Sternal fixation with a three-piece bioresorbable mesh plate could prevent postoperative sternal displacement, bleeding, and substernal hematoma more than sternal fixation with a pin.

BEYC #0293 - Bored Eye Yawn Club

A comparative study of two types of sternal pins used for sternal closure: poly-l-lactide sternal pins versus uncalcined hydroxyapatite poly-l-lactide sternal pins

Proposed algorithm for chronic post-sternotomy wounds based on the

PDF) Corrugated Sheet of Unsintered Hydroxyapatite Poly-L-Lactide for Sternal Fixation: A Preclinical Study

Bioengineering, Free Full-Text

US11006955B2 - End effectors with positive jaw opening features for use with adapters for electromechanical surgical instruments - Google Patents

MTMRecognition - Commonwealth of Virginia

US9539000B2 - Knotless suture anchor and methods of use - Google Patents

Phenomenon of dancing wires in total sternal dehiscence (male, 62

Phenomenon of dancing wires in total sternal dehiscence (male, 62

Materials and techniques in chest wall reconstruction: a review. - Abstract - Europe PMC